UART baud-rate divisor
Compute the divisor that gives the closest baud rate. An easy embedded C problem (Registers and memory-mapped I/O), run and graded in the browser.
easy · Registers and memory-mapped I/O · uart · rounding
A UART with 16x oversampling produces baud = clock / (16 * divisor).
Return the integer divisor that gives the baud rate closest to the requested one: clock_hz / (16 * baud), rounded to the nearest integer.
Starter code
uint16_t baud_divisor(uint32_t clock_hz, uint32_t baud) {
// clock / (16 * baud), rounded to nearest rather than truncated.
return 0;
}Example tests
9600 baud from 16 MHz
printf("%u\n", baud_divisor(16000000, 9600));Expected output:
104115200 baud from 16 MHz
printf("%u\n", baud_divisor(16000000, 115200));Expected output:
9Learn it first
- Registers, volatile and const · How C talks to hardware: memory-mapped registers, what volatile and const promise, register structs and read-modify-write.
More Registers and memory-mapped I/O problems
- Drive a GPIO pin · Set or clear one pin in a port's output data register.
- Read a GPIO pin · Report the level on one input pin.
- Configure a pin mode · Write a 2-bit mode field for one pin of a port.
- Atomic pin write · Change a pin with a single write to the bit set/reset register.
- Hygienic register macros · Fix four bit-manipulation macros that break on compound arguments.
- Clear a write-1-to-clear flag · Acknowledge one interrupt flag without wiping the others.
- Poll with a timeout · Wait for a status bit, but never forever.
- PWM compare value · Convert a duty cycle in percent to a timer compare value.
- Lay out a register map · Declare a peripheral struct whose members land on the right offsets.
- ADC conversion sequence · Write a 5-bit channel number into a computed slot of a register.
- Read a split counter · Read a 32-bit count from two 16-bit halves that keep changing.
- Fix: disabling one interrupt silences the timers · Clearing one bit of an interrupt-enable register clears every bit below it as well.
- Infusion pump: read the pressure, with a timeout · Start a conversion, poll its done flag, and give up safely if the converter never answers.