Water meter with shut-off (YF-S201)
Count a flow sensor's pulses to measure litres a minute and the total, and close the valve (a relay) once two litres have run.
Sensors · Intermediate
In a real product: Smart water meter (Energy): Counts flow pulses for billing and closes a valve on a leak.
A YF-S201 has a turbine inside: water spins it, and a Hall sensor gives one pulse per blade passing, 7.5 pulses a second for each litre a minute. Count them and you have a water meter. Here a relay stands in for a valve that shuts once two litres have been dispensed.
What you'll learn
- Measuring a frequency by counting pulses for a fixed time
- Keeping a running total from the same pulses: 450 of them make a litre
- Switching a relay coil through a transistor, with its flyback diode
How it works
Each rising edge on pin 2 runs onPulse(). Once a second the loop takes the count (with interrupts off for the copy), so the flow is pulses / 7.5 litres a minute and the volume pulses / 450 litres. The valve opens at the start (the relay, driven through an NPN transistor from pin 7, is energised); once the total reaches 2 L the sketch drops it.
Try this
- Click the sensor and set the flow to 10 L/min: two litres take 12 seconds.
- Change the target to 0.5 L and make the button on pin 3 start another fill.
- Real sensors read a few percent off: add a calibration factor and correct it against a measuring jug.
sketch.ino
// A water meter: a YF-S201 on pin 2 (7.5 Hz per L/min, 450 pulses a litre), a valve relay switched through a
// transistor on pin 7. The valve closes once 2 litres have flowed.
const float PULSES_PER_LITRE = 450.0, TARGET_LITRES = 2.0;
const int VALVE = 7;
volatile unsigned long pulses = 0;
unsigned long total = 0;
bool valveOpen = true;
void onPulse() { pulses++; }
void setup() {
Serial.begin(9600);
pinMode(2, INPUT);
pinMode(VALVE, OUTPUT);
digitalWrite(VALVE, HIGH);
attachInterrupt(digitalPinToInterrupt(2), onPulse, RISING);
Serial.println("Valve open");
}
void loop() {
static unsigned long lastReport = 0;
if (millis() - lastReport < 1000) return;
lastReport = millis();
noInterrupts();
unsigned long counted = pulses;
pulses = 0;
interrupts();
total += counted;
float litres = total / PULSES_PER_LITRE;
Serial.print(counted / 7.5, 1);
Serial.print(" L/min, ");
Serial.print(litres, 3);
Serial.println(" L");
if (valveOpen && litres >= TARGET_LITRES) {
valveOpen = false;
digitalWrite(VALVE, LOW);
Serial.println("Target reached: valve closed");
}
}