ECG patch: smooth the heartbeat signal
A running four-sample average that keeps a constant cost per sample and starts cleanly. A medium embedded C problem (Digital filters: FIR and IIR), run and…
medium · Digital filters: FIR and IIR · moving-average · state · rounding · product
Product: Wearable ECG patch (Medical)
Requirement. The patch removes high-frequency muscle noise from the ECG before detecting beats, on a tiny MCU sampling hundreds of times a second, so each sample must cost the same few operations.
ecg_filter takes the next sample and returns the average of the last 4 samples (fewer at the start: the average of those received so far), rounded to the nearest integer, halves away from zero. Keep a running sum: subtract the sample that drops out instead of adding all four again.
Starter code
int16_t ecg_filter(ecg_t *f, int16_t x) {
f->hist[f->idx] = x;
f->sum += x;
f->idx = (uint8_t)((f->idx + 1) % 4);
return (int16_t)(f->sum / 4);
}Example tests
A steady signal
ecg_t f;
memset(&f, 0, sizeof f);
for (int i = 0; i < 5; i++) printf("%d ", ecg_filter(&f, 100));
printf("\n");Expected output:
100 100 100 100 100A single spike spreads over four samples
ecg_t f;
memset(&f, 0, sizeof f);
int16_t x[9] = { 0, 0, 0, 0, 400, 0, 0, 0, 0 };
for (int i = 0; i < 9; i++) printf("%d ", ecg_filter(&f, x[i]));
printf("\n");Expected output:
0 0 0 0 100 100 100 100 0Learn it first
- Digital filters: FIR and IIR · Moving averages, FIR and IIR filters, biquads and notch filters.
More Digital filters: FIR and IIR problems
- Moving average with a running sum · Average the last few samples with one add and one subtract per sample.
- Exponential smoothing without stalling · A first-order IIR filter in integers that keeps extra fractional bits so it reaches the input.
- Fix: the filter output is one sample late · An FIR filter's impulse response comes out shifted by one sample.