Exponential smoothing without stalling
A first-order IIR filter in integers that keeps extra fractional bits so it reaches the input. A medium embedded C problem (Digital filters: FIR and IIR),…
medium · Digital filters: FIR and IIR · dsp · iir · fixed-point
The exponential moving average y = y + (x - y) / 2^shift smooths ADC readings with one subtract and one shift. Done in plain integers it has a flaw: once x - y is smaller than 2^shift, the step rounds to zero and y never reaches x.
Write ema_update(f, x) that keeps y in Q8 (acc holds y * 256):
- On the first sample, set the output to
xexactly. - After that,
acc += ((x << 8) - acc) >> shift. - Return the output rounded to the nearest integer:
(acc + 128) >> 8.
Inputs are ADC readings from 0 to 4095.
Starter code
uint16_t ema_update(ema_t *f, uint16_t x) {
f->acc += ((int32_t)x - f->acc) >> f->shift;
return (uint16_t)f->acc;
}Example tests
A step from 0 to 1000
ema_t f = { 0, 2, false };
step(&f, 0, 1, true);
step(&f, 1000, 6, true);
printf("\n");Expected output:
0 250 438 578 684 763 822Learn it first